Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry

The analytical performance of a low cost direct injection high efficiency nebulizer (DIHEN) with replaceable capillary is evaluated and compared with a high efficiency nebulizer HEN-cyclonic spray chamber arrangement for sample introduction at lower solution uptake rates in inductively coupled plasm...

Full description

Saved in:
Bibliographic Details
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10872/14352
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1870622004587003904
bitstream.checksum.fl_str_mv f510984c01582f1c23a928e2b33f5d61
7c020282d630887ba819753d2e4a4c58
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
bitstream.url.fl_str_mv https://saber.ucv.ve/jspui/bitstream/10872/14352/1/Microchimica%20Acta%202008.pdf
https://saber.ucv.ve/jspui/bitstream/10872/14352/2/license.txt
dc.contributor.author.none.fl_str_mv Maldonado, Domingo
Chirinos, José
Benzo, Zully
Marcano, Eunice
Gómez, Clara
Salas, Janeth Salas1
Quintal, Manuelita
D’Suze, Gina
dc.creator.fl_str_mv Maldonado, Domingo
Chirinos, José
Benzo, Zully
Marcano, Eunice
Gómez, Clara
Salas, Janeth Salas1
Quintal, Manuelita
D’Suze, Gina
dc.date.accessioned.none.fl_str_mv 2017-02-08T18:28:56Z
dc.date.available.none.fl_str_mv 2017-02-08T18:28:56Z
dc.date.issued.none.fl_str_mv 2017-02-08
dc.identifier.issn.none.fl_str_mv 0026-3672
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10872/14352
dc.language.iso.en_US.fl_str_mv en
dc.subject.en_US.fl_str_mv Replaceable capillary
direct injection
ICP-OES
dc.title.en_US.fl_str_mv Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
dc.type.en_US.fl_str_mv Article
description The analytical performance of a low cost direct injection high efficiency nebulizer (DIHEN) with replaceable capillary is evaluated and compared with a high efficiency nebulizer HEN-cyclonic spray chamber arrangement for sample introduction at lower solution uptake rates in inductively coupled plasma optical emission spectrometry (ICP-OES). The system allows the use of a replaceable capillary and optimization of the aerosol generation. The study was performed in terms of the main analytical figure of merits (i.e., sensitivity, limits of detection and signal stability) for plain water solutions and matrix effects caused by nitric acid and sodium in ICP-OES. In general, the DIHEN with replaceable capillary offers better sensitivities than the HEN-Cyclonic system and for some elements, improved detection limits (DL) in the range of 1.1–3.8 ng mL 1 for Ba,Mg, Zn 206.2–200 nm and Zn 213.8–856 nm were obtained. Strontium’s DL was comparable with both systems and those for Cd and Mn were slightly worse. Short-term precision for this unit is not as good as the HEN-Cyclonic system, but being less than 2%, it can still be considered acceptable. It was more susceptible to changes in matrix composition, being ca. 18% the acid depressive effect and 7% due to sodium with the DIHEN compared to the conventional nebulizer-spray chamber arrangement (13 and 3% acid and sodium depressive effect, respectively). The utility of the developed unit is explored analyzing three certified materials (bovine liver, rice and wheat flours) and the experimental results are within the certified values. The ability of the DIHEN with replaceable capillary to analyze real micro samples (samples reconstituted in 150 mL deionized water) was demonstrated by the determination of Ca, Cd, Cu, Mg, Mn, Sr, and Zn in individual scorpion venoms samples. One of the main advantages over other arrangements is that it can be easily constructed in the laboratory.
id SABERUCV_aa2b13d414744e162d36fc2e9cf89fac
identifier_str_mv 0026-3672
language_invalid_str_mv en
network_acronym_str SABERUCV
network_name_str Repositorio Institucional de la Universidad Central de Venezuela
oai_identifier_str oai:saber.ucv.ve:10872/14352
publishDate 2017
publishDateSort 2017
repository.mail.fl_str_mv sfwrussians@gmail.com
repository.name.fl_str_mv Saber UCV
repository_id_str
spelling Maldonado, DomingoChirinos, JoséBenzo, ZullyMarcano, EuniceGómez, ClaraSalas, Janeth Salas1Quintal, ManuelitaD’Suze, Gina2017-02-08T18:28:56Z2017-02-08T18:28:56Z2017-02-080026-3672http://hdl.handle.net/10872/14352The analytical performance of a low cost direct injection high efficiency nebulizer (DIHEN) with replaceable capillary is evaluated and compared with a high efficiency nebulizer HEN-cyclonic spray chamber arrangement for sample introduction at lower solution uptake rates in inductively coupled plasma optical emission spectrometry (ICP-OES). The system allows the use of a replaceable capillary and optimization of the aerosol generation. The study was performed in terms of the main analytical figure of merits (i.e., sensitivity, limits of detection and signal stability) for plain water solutions and matrix effects caused by nitric acid and sodium in ICP-OES. In general, the DIHEN with replaceable capillary offers better sensitivities than the HEN-Cyclonic system and for some elements, improved detection limits (DL) in the range of 1.1–3.8 ng mL 1 for Ba,Mg, Zn 206.2–200 nm and Zn 213.8–856 nm were obtained. Strontium’s DL was comparable with both systems and those for Cd and Mn were slightly worse. Short-term precision for this unit is not as good as the HEN-Cyclonic system, but being less than 2%, it can still be considered acceptable. It was more susceptible to changes in matrix composition, being ca. 18% the acid depressive effect and 7% due to sodium with the DIHEN compared to the conventional nebulizer-spray chamber arrangement (13 and 3% acid and sodium depressive effect, respectively). The utility of the developed unit is explored analyzing three certified materials (bovine liver, rice and wheat flours) and the experimental results are within the certified values. The ability of the DIHEN with replaceable capillary to analyze real micro samples (samples reconstituted in 150 mL deionized water) was demonstrated by the determination of Ca, Cd, Cu, Mg, Mn, Sr, and Zn in individual scorpion venoms samples. One of the main advantages over other arrangements is that it can be easily constructed in the laboratory.enReplaceable capillarydirect injectionICP-OESDirect injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometryArticleORIGINALMicrochimica Acta 2008.pdfMicrochimica Acta 2008.pdfapplication/pdf203356https://saber.ucv.ve/jspui/bitstream/10872/14352/1/Microchimica%20Acta%202008.pdff510984c01582f1c23a928e2b33f5d61MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81509https://saber.ucv.ve/jspui/bitstream/10872/14352/2/license.txt7c020282d630887ba819753d2e4a4c58MD5210872/14352oai:saber.ucv.ve:10872/143522017-03-13 14:55:43.189Saber UCVsfwrussians@gmail.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
spellingShingle Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
Replaceable capillary
direct injection
ICP-OES
title Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
title_full Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
title_fullStr Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
title_full_unstemmed Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
title_short Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
title_sort Direct injection nebulizer with replaceable capillary for micro samples analysis by inductively coupled plasma-optical emission spectrometry
topic Replaceable capillary
direct injection
ICP-OES
url http://hdl.handle.net/10872/14352